The FVG 60-156 photovoltaic modules are suitable for residential systems Stand-Alone, office buildings, solar power stations, solar villages, villas, mountain cottages, pumps, traffic signs, radio relay stations, telecommunication systems, telemeter systems, lighting equipment, MW ground plants. The number of the cells is 60 and the max system voltage DC is 1000V.
The FVG 60-156 photovoltaic modules are IEC 61215 certified.
Code
Type
Model
Module Efficiency
Cell Efficiency
Power
Peak(W)
Vm (V)
Im (A)
Voc
(V)
Isc
(A)
Power
Tollerance
50230
FVG 60-156
FVG 200P-MC
12,20%
13,70%
200
28,70
6,97
36,00
7,75
+/- 3%
50231
FVG 60-156
FVG 205P-MC
12,50%
14,05%
205
29,20
7,05
36,20
7,81
+/- 3%
50232
FVG 60-156
FVG 210P-MC
12,80%
14,40%
210
29,70
7,10
36,40
7,86
+/- 3%
50233
FVG 60-156
FVG 215P-MC
13,10%
14,75%
215
29,75
7,25
36,60
7,93
+/- 3%
50234
FVG 60-156
FVG 220P-MC
13,40%
15,10%
220
29,80
7,39
36,80
8,00
+/- 3%
50235
FVG 60-156
FVG 225P-MC
13,70%
15,45%
225
30,00
7,50
37,00
8,07
+/- 3%
50236
FVG 60-156
FVG 230P-MC
14,00%
15,80%
230
30,30
7,60
37,20
8,14
+/- 3%
50237
FVG 60-156
FVG 235P-MC
14,30%
16,15%
235
30,40
7,75
37,40
8,21
+/- 3%
50238
FVG 60-156
FVG 240P-MC
14,60%
16,50%
240
30,50
7,88
37,60
8,28
+/- 3%
Cell and Connection
Mono-crystalline silicon - 60 in series
Max Series Fuse
11A
Pm Temperature Coefficient
-0,45%/°C
Voc Temperature Coefficient
-0,35%/°C
Isc Temperature Coefficient
0.05%/°C
Test Condition
STC:AM=1.5 1000W/m2, Cell Temperature 25°C
NOCT
47± 2°C
Max-System Voltage (VDC)
1000
Operating Temperature / Storage Temperature
-40~+85°C
Dielectric Insulation Voltage
3000 VDC max
Limited warranty:
3-year warranty on manufacturing defects as a result of faulty workmanship or materials. Power output =80% for 25 years. The FVG 60-156 photovoltaic modules are manufactured according to the IEC 61215 standards. The FVG 60-156 photovoltaic modules are IEC 61215 certificated.
The characteristics of this document are representative of the products and have no contractual value. Subject to product improvements, we reserve the right to modify the characteristics without prior notification.